Training Collections
Library Memberships
On-demand course library with video lectures, expert case reviews, and more
Fellowship Certificate™ Programs
Practice-focused training programs designed to help you gain experience in a specific subspecialty area.
Ultimate Learning Pass
Unlock access to our full Course Library and all self-paced Fellowships.
Continuing Medical Education (State CME)
Complete all of your state CME requirements in one convenient place.
Noon Conference (Free)
Get access to free live lectures, every week, from top radiologists.
Case of the Week (Free)
Get a free weekly case delivered right to your inbox.
Case Crunch: Rapid Case Review (Free)
Register for free live board reviews.
Dr. Resnick's MSK Conference
Learn directly from the MSK Master himself.
Lower Extremities MRI Conference
Musculoskeletal Imaging
Emergency Imaging
Emergency GI & Abdominal Radiology FellowshipNEW!
PET Imaging
Pediatric Imaging
For Training Programs
Supplement your training program with case-based learning for residents, registrars, fellows, and more.
For Private Practices
Upskill in high growth, advanced imaging areas.
Compliance
NewTrack, fulfill, and report on all your radiologists' credentialing and licensing requirements.
Emergency Call Prep
Prepare trainees to be on call for the emergency department with this specialized training series.
Training Collections
Library Memberships
On-demand course library with video lectures, expert case reviews, and more
Fellowship Certificate™ Programs
Practice-focused training programs designed to help you gain experience in a specific subspecialty area.
Ultimate Learning Pass
Unlock access to our full Course Library and all self-paced Fellowships.
Continuing Medical Education (State CME)
Complete all of your state CME requirements in one convenient place.
Noon Conference (Free)
Get access to free live lectures, every week, from top radiologists.
Case of the Week (Free)
Get a free weekly case delivered right to your inbox.
Case Crunch: Rapid Case Review (Free)
Register for free live board reviews.
Dr. Resnick's MSK Conference
Learn directly from the MSK Master himself.
Lower Extremities MRI Conference
Musculoskeletal Imaging
Emergency Imaging
Emergency GI & Abdominal Radiology FellowshipNEW!
PET Imaging
Pediatric Imaging
For Training Programs
Supplement your training program with case-based learning for residents, registrars, fellows, and more.
For Private Practices
Upskill in high growth, advanced imaging areas.
Compliance
NewTrack, fulfill, and report on all your radiologists' credentialing and licensing requirements.
Emergency Call Prep
Prepare trainees to be on call for the emergency department with this specialized training series.
4 topics, 23 min. of video
6 topics, 24 min. of video
6 topics, 34 min. of video
1 topic
0:00
The object which captures to create an X-ray image is what is called as
0:04
image intensifier, and there is also newer is flat panel
0:08
detector.
0:10
Image receptor is the cylindrical tube sitting on top, focused towards
0:14
the X-ray tube, which captures the X-rays, converts into light
0:18
and the signal, and create an image. Simultaneously, you can see the image so fast.
0:23
A typical image intensifiers are usually nine
0:27
inch of II. This is what most of the mobile arm of a
0:30
nine-inch II is nine-inch diameter image
0:34
receptor.
0:37
The way if you open up this particular cylinder, you can see here the outer
0:40
side is the point which sees the patient,
0:44
has a screen diameter ranging from 15 to 40 centimeter
0:48
in diameter here. It can be small to large.
0:52
However, the output screen is still one and a half to three
0:56
centimeter, a small focal spot, the smaller output area.
1:01
The schematic diagram or principle behind image intensifier is
1:05
as follows.
1:06
When X-rays hit the image receptor, here image intensifier,
1:11
the front end of the window has a what is called as
1:14
input phosphor. The input phosphor converts X-rays
1:18
into light. That is very important.
1:21
And the light, when they interact with this photocathode
1:25
material, that converts the light into electrical
1:29
signal,
1:30
and that's what these electrons are.
1:33
These electrons are negatively charged, and they begin to get
1:36
attracted towards the anode, which is the positively charged output phosphor,
1:40
which is positively maintained at a higher positive tube voltage.
1:45
In between, you also have what is called as dynodes, which
1:48
basically functions at to focus the X-rays
1:52
towards the output phosphor rather than strain, the remaining
1:56
strain. And once the light signal hits the photocathode, the
2:00
output window, that converts that electrical signal into
2:03
light, the photons and the light photon is then transported towards
2:07
output window into a TV camera or to a computer,
2:11
everything.
2:12
So the principle behind this like in image intensifier,
2:16
X-rays are converted into light.
2:19
Light are then converts into electron, which are photoelectrons,
2:23
and these photoelectrons will result in a light signal at the
2:27
output phosphor. And that light, it can be directed into
2:31
multiple spots through and create a video signal, either a
2:35
TV or into another format, recording device, and so
2:39
forth.
Interactive Transcript
0:00
The object which captures to create an X-ray image is what is called as
0:04
image intensifier, and there is also newer is flat panel
0:08
detector.
0:10
Image receptor is the cylindrical tube sitting on top, focused towards
0:14
the X-ray tube, which captures the X-rays, converts into light
0:18
and the signal, and create an image. Simultaneously, you can see the image so fast.
0:23
A typical image intensifiers are usually nine
0:27
inch of II. This is what most of the mobile arm of a
0:30
nine-inch II is nine-inch diameter image
0:34
receptor.
0:37
The way if you open up this particular cylinder, you can see here the outer
0:40
side is the point which sees the patient,
0:44
has a screen diameter ranging from 15 to 40 centimeter
0:48
in diameter here. It can be small to large.
0:52
However, the output screen is still one and a half to three
0:56
centimeter, a small focal spot, the smaller output area.
1:01
The schematic diagram or principle behind image intensifier is
1:05
as follows.
1:06
When X-rays hit the image receptor, here image intensifier,
1:11
the front end of the window has a what is called as
1:14
input phosphor. The input phosphor converts X-rays
1:18
into light. That is very important.
1:21
And the light, when they interact with this photocathode
1:25
material, that converts the light into electrical
1:29
signal,
1:30
and that's what these electrons are.
1:33
These electrons are negatively charged, and they begin to get
1:36
attracted towards the anode, which is the positively charged output phosphor,
1:40
which is positively maintained at a higher positive tube voltage.
1:45
In between, you also have what is called as dynodes, which
1:48
basically functions at to focus the X-rays
1:52
towards the output phosphor rather than strain, the remaining
1:56
strain. And once the light signal hits the photocathode, the
2:00
output window, that converts that electrical signal into
2:03
light, the photons and the light photon is then transported towards
2:07
output window into a TV camera or to a computer,
2:11
everything.
2:12
So the principle behind this like in image intensifier,
2:16
X-rays are converted into light.
2:19
Light are then converts into electron, which are photoelectrons,
2:23
and these photoelectrons will result in a light signal at the
2:27
output phosphor. And that light, it can be directed into
2:31
multiple spots through and create a video signal, either a
2:35
TV or into another format, recording device, and so
2:39
forth.
Report
Faculty
Mahadevappa Mahesh, PhD, FACR, MS, FAAPM, FACMP, FSCCT, FIOMP
Professor of Radiology and Cardiology
Johns Hopkins University School of Medicine
Tags
Physics and Basic Science
Nuclear Medicine
Fluoroscopy
© 2026 Medality. All Rights Reserved.