Interactive Transcript
0:02
Hello, and welcome to Noon Conference hosted by Modality.
0:06
Noon Conference connects the global radiology community through free live
0:09
educational webinars that are accessible for all and is an opportunity to learn
0:13
alongside top radiologists from around the world.
0:16
Today, we are honored to welcome Dr.
0:19
Kaviani for a lecture entitled "AI-Generated
0:22
Radiology Impressions: Accuracy, Consistency, and Clinical
0:26
Potential." Dr. Kaviani is a postdoctoral research fellow at
0:30
Massachusetts General Hospital and Harvard Medical School.
0:34
Her research focuses on integrating AI into radiology workflows to
0:38
improve diagnostic accuracy, efficiency, and reporting quality.
0:42
She currently works as an image analyst at the Tumor Imaging Metrics
0:46
Core, focusing on medical image analysis for clinical
0:50
research. Dr. Kaviani has received multiple national and
0:53
international awards, including recognition from RSNA,
0:57
AAR, and WINSS, and has presented
1:01
her work at leading conferences worldwide.
1:04
She's actively involved in advancing equitable and accessible AI-driven
1:08
education in radiology.
1:10
At the end of the lecture, please join Dr.
1:12
Kaviani in a Q&A session where she will address questions you may have on today's
1:16
topic. Please remember to use the Q&A feature to submit your questions so we can
1:20
get to as many as we can before our time is up.
1:23
With that, we are ready to begin today's lecture. Dr.
1:25
Kaviani, please take it from here.
1:28
Thank you very much for the introduction.
1:31
I'm Parisa Kaviani, and I am pleased to be here
1:34
to go through one of our studies. So I'm going to go and share my
1:38
screen.
1:40
So in our study that the title is
1:43
"Artificial Intelligence-Generated Autoimpression
1:47
from 9,800
1:49
Radiology Reports: A Training Dataset from
1:53
Multiple Sites and Imaging Modalities."
1:59
As disclosure, I have nothing to disclose.
2:03
As introduction, workforce is a fundamental component
2:07
of any healthcare system. It directly affects access,
2:11
efficiency, quality, and timely delivery of care.
2:15
Radiology is particularly dependent on an
2:19
adequate workforce because imaging volumes continue to increase,
2:23
while interpretation still requires expert
2:27
physician review. The COVID-19 pandemic further
2:30
highlighted workforce vulnerabilities across healthcare.
2:35
In radiology, these challenges involve both radiologists and
2:39
technologists. This shortage has important
2:42
consequences. Delays in image acquisition
2:46
or interpretation may affect patient care, increase
2:50
turnaround at times, and contribute to radiologists'
2:54
workload and burnout. Therefore, there is increasing
2:58
interest in tools that can improve radiology workflow
3:02
without compromising diagnostic accuracy.
3:05
Artificial intelligence may provide support by automating
3:09
repetitive or time-consuming tasks.
3:12
In this context of reporting,
3:16
one such task is generation of the impression section.
3:20
The goal is not to replace radiologists, but to assist
3:23
them by reducing repetitive dictation and allowing more
3:27
time for image interpretation, clinical reasoning,
3:31
and communication.
3:36
The workforce challenge is further
3:39
intensified by increasing imaging
3:42
utilization. Prior studies have shown substantial
3:46
increases in CT, MR, and ultrasound
3:50
utilization over time. For example, CT use
3:53
increased from 56 per 1,000
3:57
individuals in 2000 to 141
4:01
per 1,000 individuals in 2016.
4:05
MR increased from 16 to 64 per 1,000
4:09
individuals, and ultrasound increased from
4:11
177 to
4:15
347 per 1,000 individuals during the same
4:18
period. In addition to the increasing number of
4:22
examinations, modern imaging studies often generate larger
4:26
and more complex datasets. This means that the radiologists
4:30
are not only interpreting more studies, but also reviewing
4:34
more images per study. Therefore, improving workflow
4:37
efficiency has become a major priority.
4:40
One area where efficiency may be improved is
4:44
the reporting process. Radiologists spend substantial time
4:48
translating imaging findings into structured written reports.
4:52
If AI can assist in generating accurate impressions from the
4:56
finding section, it may reduce reporting burden while
5:00
preserving the radiologist's final
5:02
responsibility for report review and approval.
5:09
Radiology reports are commonly structured into several
5:13
sections. This may include the imaging procedure or protocol
5:16
name, the finding section, the impression section, and
5:20
recommendations when appropriate.
5:22
The finding section contains the detailed observations from the
5:26
examination. The impression section has a different role.
5:30
It summarizes the most clinically relevant findings,
5:33
provides diagnostic interpretation, and may include
5:36
comparisons with prior imaging. This section is particularly
5:40
important because referring clinicians offer focus on the
5:43
impression when making clinical decisions.
5:46
Therefore, accurate impression generation is
5:50
essential.
5:52
An automated system must do more than produce
5:56
fluent text. It must correctly identify the findings,
6:00
avoid omitting important abnormalities, and avoid
6:03
introducing information that is not supported by
6:07
By the original report.
6:13
Generating the impression section requires additional dictation time
6:17
after the finding section has already been created.
6:21
This additional step may contribute to reporting workload,
6:25
particularly when imaging volume is high.
6:28
There is also a potential risk of discrepancy between the findings
6:32
and impression. For example, a finding described in detail may be omitted
6:36
from the impression, or the impression may contain wording that does
6:40
not fully match the findings. These discrepancies may create
6:44
confusion for referring clinicians and may affect
6:47
clinical decision-making. Therefore, AI-generated auto
6:51
impressions may help address this issue by creating a draft
6:55
impression directly from the findings section.
6:59
If accurate, this could improve efficiency and consistency.
7:02
However, because the impression has direct clinical
7:06
significance, any AI-generated output must be carefully
7:09
evaluated before implementation.
7:14
Therefore, this study was designed to compare AI-generated
7:18
impressions with radiologist-dictated impressions and
7:22
assess the accuracy of this approach.
7:24
Therefore,
7:26
what we did in this study was to compare the AI-generated auto
7:30
impression section of radiology reports with
7:33
radiologist-dictated impressions.
7:35
We also evaluated whether the AI-generated impression accurately
7:39
captured significant and incidental findings from the report.
7:44
We also assessed consistency with the original findings,
7:47
discrepancy, word count, overall quality, and
7:51
diagnostic performance.
7:57
In our study, we included 3,521
8:01
radiology reports from February to April
8:05
22, 2022. The data set
8:08
included two different data sets from one single center and the
8:12
other one multi-center
8:14
reports. The single center data set included reports from
8:18
eight radiologists, where in total
8:22
2,114 reports were
8:25
collected, and the multi-center data set include only
8:29
CT exams
8:31
of 1,407
8:34
reports.
8:35
In our study
8:37
we included multiple imaging modalities:
8:41
CT, MR, X-ray, ultrasound,
8:45
PET-CT, and there were a few other type of
8:48
examination. The single center data set included
8:52
1,073 CT scans,
8:55
76 MRI,
8:57
502 X-rays, 345 ultrasound,
9:01
88 PET-CT, and 30 other examinations.
9:07
This structure allowed us to evaluate AI-generating
9:10
impressions in both controlled single center environment
9:14
and a broader multi-center setting.
9:18
It also allowed us to assess whether the AI system performed
9:22
consistently across different radiologists and
9:25
imaging modalities. This is important because real-world
9:29
implementation requires robustness across
9:32
variable reporting styles, examination types, and
9:36
clinical contexts.
9:41
At the end, two reports were excluded because the
9:45
original report or the impression section was missing.
9:49
These reports were not included in the statistical analysis.
9:52
Then two thoracic radiologists reviewed the radiology reports
9:56
for each report. They recorded the number of incidental findings and
10:00
significant findings in both the
10:03
radiologist-dictated impression and the AI-generated auto
10:07
impression. It is important that we review the definition of significant and
10:11
incidental findings one more time.
10:13
Significant findings are imaging abnormalities that are
10:17
directly relevant to the reason for the examination, or that
10:21
may meaningfully affect diagnosis, treatment,
10:24
prognosis,
10:26
or follow-up. And incidental findings are
10:30
abnormalities discovered unintentionally that are not
10:34
directly related to the indication for the examination.
10:38
They may be still be clinically important, but they were not the
10:42
primary reason the imaging was performed.
10:44
This allowed us to compare not only whether the overall
10:48
impression appeared similar, but also whether specific clinically
10:52
relevant findings were preserved.
10:54
This distinction is important. An AI-generated
10:58
impression may appear linguistically appropriate,
11:03
but still omit an important finding.
11:05
Conversely, it may include all significant findings,
11:10
but use a slightly different wording.
11:12
Therefore, our evaluation focus on both content and
11:16
clinical relevant. The review process allowed us to assess the
11:20
accuracy of AI-generated impression at the level of
11:23
individual findings, rather than relying only on general
11:27
similarity.
11:32
The experimental auto impression generator was developed by
11:35
Nuance Communication.
11:38
The model was trained on more than
11:41
9,799,000 radiology reports from
11:45
10 healthcare centers across the United States.
11:49
During model training, report
11:53
text was normalized. Duplicate and near duplicate
11:57
reports were excluded to reduce redundancy
12:01
in the training data set. Reports were also filtered based on
12:05
token length criteria. This large training data set
12:08
is important because radiology reports vary substantially
12:12
by institution, modality, subspecialty, and
12:16
individual reporting style. Training on millions of reports
12:20
from multiple sites provide the model with
12:24
broad exposure to different reporting patterns.
12:31
The auto impression generator models impression
12:35
generation as sequence to sequence problem.
12:39
In this framework, the report content without the impression is
12:43
used as the input. The
12:46
encoder processes this report content and
12:49
convert it into a high dimensional representation.
12:53
The decoder then generates the impression autoregressively.
12:57
The model is based on a transformer neural
13:00
network architecture. The network was trained
13:04
using supervised learning on key radiology reports
13:08
and corresponding impression. Conceptually, the model
13:13
learns how radiologists convert detailed findings into
13:16
concise impression statements. This task is well suited
13:20
for transformer-based language models because it requires
13:24
understanding context, selecting relevant information,
13:28
and generating coherent clinical text.
13:35
For evaluation, radiology reports were imported into Microsoft
13:39
Access. A user-friendly data entry system was created to
13:43
present reports in a structured format for reviewer
13:46
assessment. This interface allowed reviewers to view the original
13:50
report, radiologist-dictated impression, and
13:53
AI-generated auto impression. The purpose of this system was
13:58
to standardize the review process and facilitate
14:01
consistent data entry. A structured evaluation
14:05
platform is important in studies of this type
14:10
because reviewers must assess multiple components, including
14:13
findings, impressions, discrepancy status,
14:17
and overall quality. By organizing the data in a consistent format,
14:21
we aim to improve the reliability and efficiency of the
14:25
review process.
14:28
This slide shows
14:30
a screenshot of Microsoft Access interface created for reviewing
14:33
radiology reports. And now we would go to the details of
14:37
each section.
14:41
Here you can see the original report in this box.
14:46
These two sections would show original impression
14:50
and AI impression.
14:55
This section shows the details that we quantified for original
14:59
impression, and this section shows the similar
15:02
information for AI impression.
15:08
In this section, we actually recorded the status of the finding,
15:12
whether it's remained stable, increased, decreased,
15:17
if there would be a prior exam to compare, and if there
15:21
is no prior exam, so it would be considered a new finding.
15:26
In this section, we actually counted the incidental
15:29
findings for both impression, AI impression and
15:33
original impression. In this part, we counted the
15:36
significant findings.
15:39
This section actually showed the word count for both original
15:43
impression and AI impression, which was automatically done
15:47
by, I think, Excel we used.
15:52
In this section, if there would be any laterality concern,
15:56
we record it
15:59
as perfect, acceptable, or unacceptable.
16:07
In this section, if there would be any specific note that the radiologist
16:10
or the reviewer wanted to mention which would not be included in
16:15
any of these sections, they would actually note it.
16:19
And at the end, it would be like the overall assessment based on
16:23
clinically significant impression, if it was excellent, which
16:26
means no change needed.
16:30
Oops,
16:31
sorry.
16:32
And whether it was excellent, good, which needed
16:36
minor changes, acceptable, which shows that
16:40
major change is needed but still acceptable, or
16:44
as unacceptable.
16:49
In our study,
16:50
statistical analysis was performed using Microsoft Excel version
16:54
16 and SPSS version
16:58
26. We calculated sensitivity,
17:01
specificity, AUROC, and
17:05
these metrics were used to evaluate the performance of
17:09
AI-generated impression, identifying
17:12
findings compared with radiologist-dictated impression.
17:16
We also estimated the linear correlation coefficient between word
17:20
counts for radiologist-dictated impressions and
17:23
AI-generated auto impression. This allowed us to assess whether the
17:27
AI-generated impressions were similar in length to radiology's
17:31
impressions.
17:38
This slide summarizes the word counts for
17:41
radiologist-dictated impressions and AI-generated
17:45
auto impressions. In the multi-center reports,
17:49
the mean and standard deviation
17:52
was 40 plus minus 24 words for
17:56
radiologist impression, and 37 plus minus
18:00
23 words for AI impressions. In the single
18:03
center reports, the mean and standard deviation
18:07
count was 33 plus minus
18:11
23 words for radiologist impression and
18:15
30 plus minus 22 words for AI impression.
18:20
The differences were not significant, as we can see in the P value.
18:23
These results indicate that the AI-generated impressions were
18:27
similar in length to radiologist-dictated impressions.
18:30
This is relevant because overly long impressions may reduce
18:34
readability, while
18:37
overly short impressions may omit important
18:41
information. The similarity in word count suggests that the
18:45
AI system generated impressions with lengths
18:48
comparable to routine radiologist reporting.
18:55
This slide shows consistency with the original findings.
18:59
In the multi-center dataset, radiologist-dictated
19:03
impressions were consistent with the original findings in
19:07
98% of reports, while AI-generated
19:10
impressions were consistent in
19:13
98.79%. In the single center
19:17
dataset, radiologist impressions were consistent in
19:20
98.1%, and AI-generated impressions were
19:23
consistent in 98.8%.
19:27
These results demonstrate very high consistency for both
19:31
radiologist and AI-generated impression.
19:34
Importantly, the AI-generated impressions showed
19:37
consistency rates that were comparable to
19:42
and slightly higher than radiologist-dictated impression in both
19:46
datasets. This finding supports the
19:49
potential role of AI-generated impressions as a
19:53
tool for maintaining consistency between report findings and
19:57
impression.
20:01
This slide summarizes the frequency of discrepancies in
20:05
the multi-center report. There were 28 discrepancies
20:09
in radiologist-dictated impression and 17
20:12
discrepancies in AI-generated impression.
20:16
In the single center report, there were 14 discrepancies in
20:20
radiologist impression and 29 discrepancies in
20:24
AI-generated impression.
20:27
The frequency of discrepancies was significantly higher for the radiologist
20:31
impressions than for AI impressions in both single
20:35
center and multi-center reports.
20:38
This is an important finding. It suggests that AI-generated
20:41
impressions may help reduce certain inconsistencies between the
20:45
findings and impression sections.
20:48
One possible explanation is that the AI system generates the impression
20:51
directly from the findings section, which may reduce the chance of
20:55
mismatch.
21:01
This slide shows the correlation between radiologist-dictated
21:05
impressions and AI-generated impressions for
21:08
significant and incidental findings.
21:11
For significant findings, the correlation coefficient was
21:15
0.003
21:18
in multi-center reports and 0.887
21:22
in single center reports. For incidental findings, the
21:25
correlation coefficient was a bit lower, which was
21:28
0.743 in multi-center reports
21:32
and 0.717 in single center report.
21:35
All correlations were statistically significant,
21:40
as we can see in the P value. These results show strong correlation
21:43
between AI-generated and radiologist-generated impressions,
21:48
particularly for significant findings.
21:50
The correlation was lower for incidental findings.
21:53
This may reflect the fact that incidental findings are often more
21:57
variable in how radiologists choose to report them.
22:01
Some radiologists may include certain incidental findings in
22:04
impression, while others may leave them only in the findings
22:08
section. Therefore, the lower correlation for incidental findings may
22:12
reflect variability in reporting practice rather than failure
22:16
of the AI system alone.
22:24
This slide provides a detailed summary of number of
22:28
incidental and significant findings per report
22:31
for both radiologist-dictated impressions and
22:35
AI-generated impressions. The table shows the
22:38
distribution of reports containing zero, one, two, three, and more
22:42
findings. Overall, the distributions between radiologist-dictated and
22:46
AI-generated impression
22:49
were similar across both single center and multi-center datasets.
22:54
For significant findings, most reports contained one
22:58
or two key findings.
23:02
For incidental findings, many reports contain no incidental findings, while
23:06
a smaller portion contains one or more.
23:09
This table is important because
23:13
it demonstrates that the AI-generated impressions did not
23:17
simply produce generic summaries.
23:19
Instead, the AI outputs reflected a similar distribution
23:23
of finding counts compared with radiologist
23:27
impressions. This supports the ability of the AI system to
23:30
capture the structure and content density of
23:34
radiologist-dictated impressions.
23:41
This slide summarizes the overall assessment of AI-generated
23:45
impressions. In the multi-center reports,
23:50
66.7% of AI-generated impressions
23:54
were classified as perfect. An additional
23:56
23.2% were classified as good.
24:01
8% required major changes and 2.1% were
24:05
considered unacceptable.
24:08
In the single center reports,
24:10
66.3% were classified
24:13
perfect,
24:15
24.7% were good, 8%
24:19
required major changes, and only
24:22
1.6% were unacceptable. These findings are
24:26
clinically meaningful. Approximately two-thirds of AI-generated
24:30
impressions were considered perfect and nearly
24:33
one-quarter were considered good.
24:35
Therefore, the majority of AI-generated impressions
24:39
were either directly acceptable or required only limited
24:43
modification.
24:45
At the same time, the presence of major change and unacceptable
24:49
categories is important. These cases demonstrate that
24:52
radiologist review remains essential.
24:55
AI-generated impressions may improve efficiency, but they
24:59
should not be used without physician verification.
25:06
This slide summarizes additional performance results.
25:09
There were no significant variation in generated impression
25:13
performance or correlation with radiologist-dictated
25:16
impressions across different imaging modalities or across
25:20
the eight radiologists in the single center dataset.
25:25
This suggests that the AI system performed consistently across
25:29
the evaluated modalities and across different
25:32
radiologists' reporting style.
25:36
The AUC was also assessed for incidental and
25:39
clinically significant findings.
25:42
For incidental findings, the AUC was 0.76
25:46
in single center reports and 0.68 in
25:49
multi-center reports. For clinically significant
25:53
findings, the AUC was 0.76 in single
25:56
center report
25:58
and 0.81 in multi-center reports.
26:01
These AUC values indicate reasonable diagnostic performance,
26:06
particularly for clinically significant findings
26:10
in the multi-center dataset. Overall, these results support the
26:14
robustness of AI-generated impression performance across different
26:18
clinical settings, while still emphasizing the need for review
26:22
in individual cases.
26:27
Now we'll go through some of the examples that we actually faced
26:31
the time that we were reviewing. This example demonstrates an
26:35
AI-generated impression that required no
26:38
modification. The examination was contrast-enhanced
26:42
CT of the neck. The finding described post-treatment
26:46
changes without evidence of a new nodular mass or
26:50
abnormal enhancement. There was no cervical lymphadenopathy.
26:54
The AI was able to
26:56
state that the primary site
27:00
was response with no evidence of recurrence and
27:04
expected post-treatment changes.
27:06
As you can see, they are almost identical,
27:09
the AI impression and final impression.
27:16
This example also demonstrates an AI-generated impression that
27:20
required no modification.
27:23
The examination was an abdominal radiograph performed
27:27
to evaluate entry tube placement.
27:31
The findings showed that the entry tube extended below
27:35
the diaphragm with the tip coil at the expected location of the
27:39
gastric fundus. As we can see that the final
27:42
impression and AI impression
27:45
were somehow identical,
27:49
and there was no need to make any changes.
27:56
This is an example which shows that minor
28:00
changes were needed. This example demonstrates an
28:04
AI-generated impression that was
28:08
from a right foot radiograph. The finding describes soft tissue
28:12
swelling of the great toe and a linear lucency
28:16
involving the proximal first phalanx
28:19
extending to the interphalangeal joint.
28:22
This was concerning for an intra-articular fracture.
28:26
The AI-generated impression correctly identified the principal
28:30
abnormalities as a first proximal phalanx intra-articular
28:33
fracture. The final impression included the same fracture
28:37
diagnosis, but also stated that there was
28:41
hindfoot valgus. Therefore, the AI-generated
28:44
impression captured the main acute finding
28:48
but missed an additional finding included by the radiologist,
28:52
which was one of the minor discrepancies.
28:58
This is another example
29:01
that the examination was a renal ultrasound performed for kidney
29:04
stone.
29:06
The findings showed preserved renal parenchymal thickness
29:09
and echogenicity, no hydronephrosis, and a
29:13
four-millimeter echogenic focus in the interpolar
29:17
region of the right kidney. The final
29:20
radiologist impression included the three
29:23
points as no hydronephrosis, a punctate echogenic
29:27
focus that could represent a
29:29
non-obstructing stone,
29:33
and small bilateral kidneys.
29:36
So we can see that AI-generated impression correctly identified
29:40
the absence of the hydronephrosis and the possibility
29:44
of non-obstructing right renal stone.
29:47
However, it did not include the small size of both kidneys.
29:51
The primary clinical indication was therefore addressed correctly,
29:55
but an additional relevant finding was missed.
30:03
This example demonstrated a case requiring major modification.
30:07
The examination was a complete pediatric abdominal
30:10
ultrasound. The findings included multiple
30:14
tiny hyperechoic
30:17
foci in the liver and spleen, the
30:20
compressed gallbladder with sludge, pleuritis
30:25
An apparent increased echogenicity of both kidneys.
30:28
AI captured most of the findings. However, the
30:32
final radiologist report and
30:35
impression provided more specific diagnostic
30:39
interpretation for the liver and
30:43
the spleen, where I did not mention them.
30:51
And this example also is one of another major discrepancies.
30:55
The examination was a contrast enhancement CT of the thoracic
30:59
spine in patient with metastatic disease and prior thoracic
31:03
spine surgery. The finding described prior
31:07
T9 through L1 posterior fusion and
31:10
T11
31:12
corpectomy with stable hardware alignment.
31:15
They also described a marrow replacement process
31:19
involving the T11 vertebral body and a large right
31:23
pleural effusion. The final impression emphasized stable
31:26
postoperative changes, no additional obvious lytic mass
31:30
lesion, and a larger right-sided pleural effusion with
31:34
decreased left-sided pleural effusion.
31:37
And as you can see, the AI-generated impression correctly
31:41
described the prior fusion and corpectomy with stable
31:45
hardware alignment. However, it also included the marrow
31:49
replacement process involving C11 and
31:52
generated the recommendation as recommended
31:56
oncology follow-up. This recommendation was not included
32:00
in the final radiologist impression.
32:03
This example demonstrates an important safety issue.
32:06
AI systems may generate statements that appear
32:10
clinically plausible but are not part of the
32:13
radiologist's intended conclusion.
32:16
Therefore, even when AI performance is strong
32:19
overall, individual outputs must be reviewed carefully.
32:23
AI-generated impression should be considered as assistive tool,
32:27
not an autonomous supporting system.
32:33
And in
32:37
conclusion, our study demonstrated that
32:39
AI-generated auto impressions can produce
32:43
highly accurate impressions from radiology findings
32:48
across reporting sites and imaging examinations,
32:51
thoracic, and abdominal radiology reports.
32:55
The AI-generated impressions were similar in word count to
32:59
radiologist-dictated impressions, showed high consistency
33:03
with the original findings, and demonstrated strong
33:06
correlation with the radiologist impressions, particularly for clinically
33:10
significant findings. Most AI-generated impressions were
33:14
classified as either perfect or good.
33:17
These findings support the potential role of AI-generated
33:21
impression as an assistive tool for
33:25
improving reporting efficiency.
33:27
However, the examples also demonstrate that clinically meaningful
33:31
discrepancy can occur. Therefore, radiologist
33:34
review remains essential before final report
33:38
approval. Overall, AI-generated auto
33:41
impression may help reduce reporting burden, improve
33:45
consistency, and support workflow efficiency
33:49
while maintaining the radiologist's central role
33:53
in clinical interpretation and final decision-making.
33:57
So thank you everyone for attending this session.
34:00
If there is any question, feel free to ask.
34:12
I can see a few question over here.
34:28
You have focused on impressions. Have you developed software to
34:32
auto-populate the indication section with patient age, sex, and
34:36
clinical indication from referral form and EMR?
34:40
So actually, really good question.
34:43
In this specific AI model, which was developed
34:47
by Nuance Communications, they did not focus on
34:51
this part, and we haven't worked on this part, but this is actually a really nice
34:54
question. And actually, it has
34:58
potential to be worked on. But it was not our focus to work
35:01
on.
35:10
Another question is how many versions of software tested version?
35:15
What is now available? So the thing is, this
35:19
study actually was performed,
35:22
I think, two years ago. Since then, there were a lot of updates and upgrades in
35:26
the
35:28
AI model, especially for the recommendation section.
35:33
And we have been working on another study, which
35:37
would also include the recommendations, and it actually improved
35:41
much better. But
35:44
about how many, like they may be available, to be honest,
35:50
I'm not sure right now, but I know since we worked on this
35:54
study, at least there were three or four more upgrades, which
35:58
right now it's being used in different
36:03
centers.
36:04
And actually, the results were satisfying, to be honest.
36:09
Let me see.
36:22
Actually, this question is really nice, which is for a large radiology
36:26
department, how feasible is it to deploy a local
36:29
LLM on our own reports for draft
36:33
impressions when commercial tools are limited by cost,
36:36
governance, or institutional approval?
36:39
To be honest, because I am in the-- I don't have that much
36:43
experience with this part, I believe that is a better question to be asked from
36:47
a
36:49
computer scientist. But
36:52
I feel this is really actually good question.
36:54
But to be honest,
36:56
I don't have a proper answer for this one.
37:01
I think we addressed all the question I see.
37:04
So thank you, everyone.
37:10
Excellent.
37:13
Good job answering all those questions, doctor.
37:16
Thank you.
37:19
Dr. Kamiani, thank you for your lecture today,
37:23
and thank you for everyone that joined us
37:26
and asked such great questions.
37:29
You can access a recording of today's conference and all our previous noon
37:32
conferences by creating a free account.
37:35
We'll also email out a link to the replay later today.
37:39
Be sure to join us next week on Thursday, August 20th at 12:00 PM
37:43
Eastern, where Dr. Donald Resnick will deliver a lecture
37:47
entitled "Injuries of the Knee: From Conventional Radiography to
37:50
MR Imaging." You can register for that at medallia.com and follow
37:54
us on social media for updates on future noon conferences.
37:58
Thanks again and have a great day.