Upcoming Events
Log In
Pricing
Free Trial

AI-Generated Radiology Impressions: Accuracy, Consistency, and Clinical Potential, Dr. Parisa Kaviani (8-13-26)

HIDE
PrevNext

0:02

Hello, and welcome to Noon Conference hosted by Modality.

0:06

Noon Conference connects the global radiology community through free live

0:09

educational webinars that are accessible for all and is an opportunity to learn

0:13

alongside top radiologists from around the world.

0:16

Today, we are honored to welcome Dr.

0:19

Kaviani for a lecture entitled "AI-Generated

0:22

Radiology Impressions: Accuracy, Consistency, and Clinical

0:26

Potential." Dr. Kaviani is a postdoctoral research fellow at

0:30

Massachusetts General Hospital and Harvard Medical School.

0:34

Her research focuses on integrating AI into radiology workflows to

0:38

improve diagnostic accuracy, efficiency, and reporting quality.

0:42

She currently works as an image analyst at the Tumor Imaging Metrics

0:46

Core, focusing on medical image analysis for clinical

0:50

research. Dr. Kaviani has received multiple national and

0:53

international awards, including recognition from RSNA,

0:57

AAR, and WINSS, and has presented

1:01

her work at leading conferences worldwide.

1:04

She's actively involved in advancing equitable and accessible AI-driven

1:08

education in radiology.

1:10

At the end of the lecture, please join Dr.

1:12

Kaviani in a Q&A session where she will address questions you may have on today's

1:16

topic. Please remember to use the Q&A feature to submit your questions so we can

1:20

get to as many as we can before our time is up.

1:23

With that, we are ready to begin today's lecture. Dr.

1:25

Kaviani, please take it from here.

1:28

Thank you very much for the introduction.

1:31

I'm Parisa Kaviani, and I am pleased to be here

1:34

to go through one of our studies. So I'm going to go and share my

1:38

screen.

1:40

So in our study that the title is

1:43

"Artificial Intelligence-Generated Autoimpression

1:47

from 9,800

1:49

Radiology Reports: A Training Dataset from

1:53

Multiple Sites and Imaging Modalities."

1:59

As disclosure, I have nothing to disclose.

2:03

As introduction, workforce is a fundamental component

2:07

of any healthcare system. It directly affects access,

2:11

efficiency, quality, and timely delivery of care.

2:15

Radiology is particularly dependent on an

2:19

adequate workforce because imaging volumes continue to increase,

2:23

while interpretation still requires expert

2:27

physician review. The COVID-19 pandemic further

2:30

highlighted workforce vulnerabilities across healthcare.

2:35

In radiology, these challenges involve both radiologists and

2:39

technologists. This shortage has important

2:42

consequences. Delays in image acquisition

2:46

or interpretation may affect patient care, increase

2:50

turnaround at times, and contribute to radiologists'

2:54

workload and burnout. Therefore, there is increasing

2:58

interest in tools that can improve radiology workflow

3:02

without compromising diagnostic accuracy.

3:05

Artificial intelligence may provide support by automating

3:09

repetitive or time-consuming tasks.

3:12

In this context of reporting,

3:16

one such task is generation of the impression section.

3:20

The goal is not to replace radiologists, but to assist

3:23

them by reducing repetitive dictation and allowing more

3:27

time for image interpretation, clinical reasoning,

3:31

and communication.

3:36

The workforce challenge is further

3:39

intensified by increasing imaging

3:42

utilization. Prior studies have shown substantial

3:46

increases in CT, MR, and ultrasound

3:50

utilization over time. For example, CT use

3:53

increased from 56 per 1,000

3:57

individuals in 2000 to 141

4:01

per 1,000 individuals in 2016.

4:05

MR increased from 16 to 64 per 1,000

4:09

individuals, and ultrasound increased from

4:11

177 to

4:15

347 per 1,000 individuals during the same

4:18

period. In addition to the increasing number of

4:22

examinations, modern imaging studies often generate larger

4:26

and more complex datasets. This means that the radiologists

4:30

are not only interpreting more studies, but also reviewing

4:34

more images per study. Therefore, improving workflow

4:37

efficiency has become a major priority.

4:40

One area where efficiency may be improved is

4:44

the reporting process. Radiologists spend substantial time

4:48

translating imaging findings into structured written reports.

4:52

If AI can assist in generating accurate impressions from the

4:56

finding section, it may reduce reporting burden while

5:00

preserving the radiologist's final

5:02

responsibility for report review and approval.

5:09

Radiology reports are commonly structured into several

5:13

sections. This may include the imaging procedure or protocol

5:16

name, the finding section, the impression section, and

5:20

recommendations when appropriate.

5:22

The finding section contains the detailed observations from the

5:26

examination. The impression section has a different role.

5:30

It summarizes the most clinically relevant findings,

5:33

provides diagnostic interpretation, and may include

5:36

comparisons with prior imaging. This section is particularly

5:40

important because referring clinicians offer focus on the

5:43

impression when making clinical decisions.

5:46

Therefore, accurate impression generation is

5:50

essential.

5:52

An automated system must do more than produce

5:56

fluent text. It must correctly identify the findings,

6:00

avoid omitting important abnormalities, and avoid

6:03

introducing information that is not supported by

6:07

By the original report.

6:13

Generating the impression section requires additional dictation time

6:17

after the finding section has already been created.

6:21

This additional step may contribute to reporting workload,

6:25

particularly when imaging volume is high.

6:28

There is also a potential risk of discrepancy between the findings

6:32

and impression. For example, a finding described in detail may be omitted

6:36

from the impression, or the impression may contain wording that does

6:40

not fully match the findings. These discrepancies may create

6:44

confusion for referring clinicians and may affect

6:47

clinical decision-making. Therefore, AI-generated auto

6:51

impressions may help address this issue by creating a draft

6:55

impression directly from the findings section.

6:59

If accurate, this could improve efficiency and consistency.

7:02

However, because the impression has direct clinical

7:06

significance, any AI-generated output must be carefully

7:09

evaluated before implementation.

7:14

Therefore, this study was designed to compare AI-generated

7:18

impressions with radiologist-dictated impressions and

7:22

assess the accuracy of this approach.

7:24

Therefore,

7:26

what we did in this study was to compare the AI-generated auto

7:30

impression section of radiology reports with

7:33

radiologist-dictated impressions.

7:35

We also evaluated whether the AI-generated impression accurately

7:39

captured significant and incidental findings from the report.

7:44

We also assessed consistency with the original findings,

7:47

discrepancy, word count, overall quality, and

7:51

diagnostic performance.

7:57

In our study, we included 3,521

8:01

radiology reports from February to April

8:05

22, 2022. The data set

8:08

included two different data sets from one single center and the

8:12

other one multi-center

8:14

reports. The single center data set included reports from

8:18

eight radiologists, where in total

8:22

2,114 reports were

8:25

collected, and the multi-center data set include only

8:29

CT exams

8:31

of 1,407

8:34

reports.

8:35

In our study

8:37

we included multiple imaging modalities:

8:41

CT, MR, X-ray, ultrasound,

8:45

PET-CT, and there were a few other type of

8:48

examination. The single center data set included

8:52

1,073 CT scans,

8:55

76 MRI,

8:57

502 X-rays, 345 ultrasound,

9:01

88 PET-CT, and 30 other examinations.

9:07

This structure allowed us to evaluate AI-generating

9:10

impressions in both controlled single center environment

9:14

and a broader multi-center setting.

9:18

It also allowed us to assess whether the AI system performed

9:22

consistently across different radiologists and

9:25

imaging modalities. This is important because real-world

9:29

implementation requires robustness across

9:32

variable reporting styles, examination types, and

9:36

clinical contexts.

9:41

At the end, two reports were excluded because the

9:45

original report or the impression section was missing.

9:49

These reports were not included in the statistical analysis.

9:52

Then two thoracic radiologists reviewed the radiology reports

9:56

for each report. They recorded the number of incidental findings and

10:00

significant findings in both the

10:03

radiologist-dictated impression and the AI-generated auto

10:07

impression. It is important that we review the definition of significant and

10:11

incidental findings one more time.

10:13

Significant findings are imaging abnormalities that are

10:17

directly relevant to the reason for the examination, or that

10:21

may meaningfully affect diagnosis, treatment,

10:24

prognosis,

10:26

or follow-up. And incidental findings are

10:30

abnormalities discovered unintentionally that are not

10:34

directly related to the indication for the examination.

10:38

They may be still be clinically important, but they were not the

10:42

primary reason the imaging was performed.

10:44

This allowed us to compare not only whether the overall

10:48

impression appeared similar, but also whether specific clinically

10:52

relevant findings were preserved.

10:54

This distinction is important. An AI-generated

10:58

impression may appear linguistically appropriate,

11:03

but still omit an important finding.

11:05

Conversely, it may include all significant findings,

11:10

but use a slightly different wording.

11:12

Therefore, our evaluation focus on both content and

11:16

clinical relevant. The review process allowed us to assess the

11:20

accuracy of AI-generated impression at the level of

11:23

individual findings, rather than relying only on general

11:27

similarity.

11:32

The experimental auto impression generator was developed by

11:35

Nuance Communication.

11:38

The model was trained on more than

11:41

9,799,000 radiology reports from

11:45

10 healthcare centers across the United States.

11:49

During model training, report

11:53

text was normalized. Duplicate and near duplicate

11:57

reports were excluded to reduce redundancy

12:01

in the training data set. Reports were also filtered based on

12:05

token length criteria. This large training data set

12:08

is important because radiology reports vary substantially

12:12

by institution, modality, subspecialty, and

12:16

individual reporting style. Training on millions of reports

12:20

from multiple sites provide the model with

12:24

broad exposure to different reporting patterns.

12:31

The auto impression generator models impression

12:35

generation as sequence to sequence problem.

12:39

In this framework, the report content without the impression is

12:43

used as the input. The

12:46

encoder processes this report content and

12:49

convert it into a high dimensional representation.

12:53

The decoder then generates the impression autoregressively.

12:57

The model is based on a transformer neural

13:00

network architecture. The network was trained

13:04

using supervised learning on key radiology reports

13:08

and corresponding impression. Conceptually, the model

13:13

learns how radiologists convert detailed findings into

13:16

concise impression statements. This task is well suited

13:20

for transformer-based language models because it requires

13:24

understanding context, selecting relevant information,

13:28

and generating coherent clinical text.

13:35

For evaluation, radiology reports were imported into Microsoft

13:39

Access. A user-friendly data entry system was created to

13:43

present reports in a structured format for reviewer

13:46

assessment. This interface allowed reviewers to view the original

13:50

report, radiologist-dictated impression, and

13:53

AI-generated auto impression. The purpose of this system was

13:58

to standardize the review process and facilitate

14:01

consistent data entry. A structured evaluation

14:05

platform is important in studies of this type

14:10

because reviewers must assess multiple components, including

14:13

findings, impressions, discrepancy status,

14:17

and overall quality. By organizing the data in a consistent format,

14:21

we aim to improve the reliability and efficiency of the

14:25

review process.

14:28

This slide shows

14:30

a screenshot of Microsoft Access interface created for reviewing

14:33

radiology reports. And now we would go to the details of

14:37

each section.

14:41

Here you can see the original report in this box.

14:46

These two sections would show original impression

14:50

and AI impression.

14:55

This section shows the details that we quantified for original

14:59

impression, and this section shows the similar

15:02

information for AI impression.

15:08

In this section, we actually recorded the status of the finding,

15:12

whether it's remained stable, increased, decreased,

15:17

if there would be a prior exam to compare, and if there

15:21

is no prior exam, so it would be considered a new finding.

15:26

In this section, we actually counted the incidental

15:29

findings for both impression, AI impression and

15:33

original impression. In this part, we counted the

15:36

significant findings.

15:39

This section actually showed the word count for both original

15:43

impression and AI impression, which was automatically done

15:47

by, I think, Excel we used.

15:52

In this section, if there would be any laterality concern,

15:56

we record it

15:59

as perfect, acceptable, or unacceptable.

16:07

In this section, if there would be any specific note that the radiologist

16:10

or the reviewer wanted to mention which would not be included in

16:15

any of these sections, they would actually note it.

16:19

And at the end, it would be like the overall assessment based on

16:23

clinically significant impression, if it was excellent, which

16:26

means no change needed.

16:30

Oops,

16:31

sorry.

16:32

And whether it was excellent, good, which needed

16:36

minor changes, acceptable, which shows that

16:40

major change is needed but still acceptable, or

16:44

as unacceptable.

16:49

In our study,

16:50

statistical analysis was performed using Microsoft Excel version

16:54

16 and SPSS version

16:58

26. We calculated sensitivity,

17:01

specificity, AUROC, and

17:05

these metrics were used to evaluate the performance of

17:09

AI-generated impression, identifying

17:12

findings compared with radiologist-dictated impression.

17:16

We also estimated the linear correlation coefficient between word

17:20

counts for radiologist-dictated impressions and

17:23

AI-generated auto impression. This allowed us to assess whether the

17:27

AI-generated impressions were similar in length to radiology's

17:31

impressions.

17:38

This slide summarizes the word counts for

17:41

radiologist-dictated impressions and AI-generated

17:45

auto impressions. In the multi-center reports,

17:49

the mean and standard deviation

17:52

was 40 plus minus 24 words for

17:56

radiologist impression, and 37 plus minus

18:00

23 words for AI impressions. In the single

18:03

center reports, the mean and standard deviation

18:07

count was 33 plus minus

18:11

23 words for radiologist impression and

18:15

30 plus minus 22 words for AI impression.

18:20

The differences were not significant, as we can see in the P value.

18:23

These results indicate that the AI-generated impressions were

18:27

similar in length to radiologist-dictated impressions.

18:30

This is relevant because overly long impressions may reduce

18:34

readability, while

18:37

overly short impressions may omit important

18:41

information. The similarity in word count suggests that the

18:45

AI system generated impressions with lengths

18:48

comparable to routine radiologist reporting.

18:55

This slide shows consistency with the original findings.

18:59

In the multi-center dataset, radiologist-dictated

19:03

impressions were consistent with the original findings in

19:07

98% of reports, while AI-generated

19:10

impressions were consistent in

19:13

98.79%. In the single center

19:17

dataset, radiologist impressions were consistent in

19:20

98.1%, and AI-generated impressions were

19:23

consistent in 98.8%.

19:27

These results demonstrate very high consistency for both

19:31

radiologist and AI-generated impression.

19:34

Importantly, the AI-generated impressions showed

19:37

consistency rates that were comparable to

19:42

and slightly higher than radiologist-dictated impression in both

19:46

datasets. This finding supports the

19:49

potential role of AI-generated impressions as a

19:53

tool for maintaining consistency between report findings and

19:57

impression.

20:01

This slide summarizes the frequency of discrepancies in

20:05

the multi-center report. There were 28 discrepancies

20:09

in radiologist-dictated impression and 17

20:12

discrepancies in AI-generated impression.

20:16

In the single center report, there were 14 discrepancies in

20:20

radiologist impression and 29 discrepancies in

20:24

AI-generated impression.

20:27

The frequency of discrepancies was significantly higher for the radiologist

20:31

impressions than for AI impressions in both single

20:35

center and multi-center reports.

20:38

This is an important finding. It suggests that AI-generated

20:41

impressions may help reduce certain inconsistencies between the

20:45

findings and impression sections.

20:48

One possible explanation is that the AI system generates the impression

20:51

directly from the findings section, which may reduce the chance of

20:55

mismatch.

21:01

This slide shows the correlation between radiologist-dictated

21:05

impressions and AI-generated impressions for

21:08

significant and incidental findings.

21:11

For significant findings, the correlation coefficient was

21:15

0.003

21:18

in multi-center reports and 0.887

21:22

in single center reports. For incidental findings, the

21:25

correlation coefficient was a bit lower, which was

21:28

0.743 in multi-center reports

21:32

and 0.717 in single center report.

21:35

All correlations were statistically significant,

21:40

as we can see in the P value. These results show strong correlation

21:43

between AI-generated and radiologist-generated impressions,

21:48

particularly for significant findings.

21:50

The correlation was lower for incidental findings.

21:53

This may reflect the fact that incidental findings are often more

21:57

variable in how radiologists choose to report them.

22:01

Some radiologists may include certain incidental findings in

22:04

impression, while others may leave them only in the findings

22:08

section. Therefore, the lower correlation for incidental findings may

22:12

reflect variability in reporting practice rather than failure

22:16

of the AI system alone.

22:24

This slide provides a detailed summary of number of

22:28

incidental and significant findings per report

22:31

for both radiologist-dictated impressions and

22:35

AI-generated impressions. The table shows the

22:38

distribution of reports containing zero, one, two, three, and more

22:42

findings. Overall, the distributions between radiologist-dictated and

22:46

AI-generated impression

22:49

were similar across both single center and multi-center datasets.

22:54

For significant findings, most reports contained one

22:58

or two key findings.

23:02

For incidental findings, many reports contain no incidental findings, while

23:06

a smaller portion contains one or more.

23:09

This table is important because

23:13

it demonstrates that the AI-generated impressions did not

23:17

simply produce generic summaries.

23:19

Instead, the AI outputs reflected a similar distribution

23:23

of finding counts compared with radiologist

23:27

impressions. This supports the ability of the AI system to

23:30

capture the structure and content density of

23:34

radiologist-dictated impressions.

23:41

This slide summarizes the overall assessment of AI-generated

23:45

impressions. In the multi-center reports,

23:50

66.7% of AI-generated impressions

23:54

were classified as perfect. An additional

23:56

23.2% were classified as good.

24:01

8% required major changes and 2.1% were

24:05

considered unacceptable.

24:08

In the single center reports,

24:10

66.3% were classified

24:13

perfect,

24:15

24.7% were good, 8%

24:19

required major changes, and only

24:22

1.6% were unacceptable. These findings are

24:26

clinically meaningful. Approximately two-thirds of AI-generated

24:30

impressions were considered perfect and nearly

24:33

one-quarter were considered good.

24:35

Therefore, the majority of AI-generated impressions

24:39

were either directly acceptable or required only limited

24:43

modification.

24:45

At the same time, the presence of major change and unacceptable

24:49

categories is important. These cases demonstrate that

24:52

radiologist review remains essential.

24:55

AI-generated impressions may improve efficiency, but they

24:59

should not be used without physician verification.

25:06

This slide summarizes additional performance results.

25:09

There were no significant variation in generated impression

25:13

performance or correlation with radiologist-dictated

25:16

impressions across different imaging modalities or across

25:20

the eight radiologists in the single center dataset.

25:25

This suggests that the AI system performed consistently across

25:29

the evaluated modalities and across different

25:32

radiologists' reporting style.

25:36

The AUC was also assessed for incidental and

25:39

clinically significant findings.

25:42

For incidental findings, the AUC was 0.76

25:46

in single center reports and 0.68 in

25:49

multi-center reports. For clinically significant

25:53

findings, the AUC was 0.76 in single

25:56

center report

25:58

and 0.81 in multi-center reports.

26:01

These AUC values indicate reasonable diagnostic performance,

26:06

particularly for clinically significant findings

26:10

in the multi-center dataset. Overall, these results support the

26:14

robustness of AI-generated impression performance across different

26:18

clinical settings, while still emphasizing the need for review

26:22

in individual cases.

26:27

Now we'll go through some of the examples that we actually faced

26:31

the time that we were reviewing. This example demonstrates an

26:35

AI-generated impression that required no

26:38

modification. The examination was contrast-enhanced

26:42

CT of the neck. The finding described post-treatment

26:46

changes without evidence of a new nodular mass or

26:50

abnormal enhancement. There was no cervical lymphadenopathy.

26:54

The AI was able to

26:56

state that the primary site

27:00

was response with no evidence of recurrence and

27:04

expected post-treatment changes.

27:06

As you can see, they are almost identical,

27:09

the AI impression and final impression.

27:16

This example also demonstrates an AI-generated impression that

27:20

required no modification.

27:23

The examination was an abdominal radiograph performed

27:27

to evaluate entry tube placement.

27:31

The findings showed that the entry tube extended below

27:35

the diaphragm with the tip coil at the expected location of the

27:39

gastric fundus. As we can see that the final

27:42

impression and AI impression

27:45

were somehow identical,

27:49

and there was no need to make any changes.

27:56

This is an example which shows that minor

28:00

changes were needed. This example demonstrates an

28:04

AI-generated impression that was

28:08

from a right foot radiograph. The finding describes soft tissue

28:12

swelling of the great toe and a linear lucency

28:16

involving the proximal first phalanx

28:19

extending to the interphalangeal joint.

28:22

This was concerning for an intra-articular fracture.

28:26

The AI-generated impression correctly identified the principal

28:30

abnormalities as a first proximal phalanx intra-articular

28:33

fracture. The final impression included the same fracture

28:37

diagnosis, but also stated that there was

28:41

hindfoot valgus. Therefore, the AI-generated

28:44

impression captured the main acute finding

28:48

but missed an additional finding included by the radiologist,

28:52

which was one of the minor discrepancies.

28:58

This is another example

29:01

that the examination was a renal ultrasound performed for kidney

29:04

stone.

29:06

The findings showed preserved renal parenchymal thickness

29:09

and echogenicity, no hydronephrosis, and a

29:13

four-millimeter echogenic focus in the interpolar

29:17

region of the right kidney. The final

29:20

radiologist impression included the three

29:23

points as no hydronephrosis, a punctate echogenic

29:27

focus that could represent a

29:29

non-obstructing stone,

29:33

and small bilateral kidneys.

29:36

So we can see that AI-generated impression correctly identified

29:40

the absence of the hydronephrosis and the possibility

29:44

of non-obstructing right renal stone.

29:47

However, it did not include the small size of both kidneys.

29:51

The primary clinical indication was therefore addressed correctly,

29:55

but an additional relevant finding was missed.

30:03

This example demonstrated a case requiring major modification.

30:07

The examination was a complete pediatric abdominal

30:10

ultrasound. The findings included multiple

30:14

tiny hyperechoic

30:17

foci in the liver and spleen, the

30:20

compressed gallbladder with sludge, pleuritis

30:25

An apparent increased echogenicity of both kidneys.

30:28

AI captured most of the findings. However, the

30:32

final radiologist report and

30:35

impression provided more specific diagnostic

30:39

interpretation for the liver and

30:43

the spleen, where I did not mention them.

30:51

And this example also is one of another major discrepancies.

30:55

The examination was a contrast enhancement CT of the thoracic

30:59

spine in patient with metastatic disease and prior thoracic

31:03

spine surgery. The finding described prior

31:07

T9 through L1 posterior fusion and

31:10

T11

31:12

corpectomy with stable hardware alignment.

31:15

They also described a marrow replacement process

31:19

involving the T11 vertebral body and a large right

31:23

pleural effusion. The final impression emphasized stable

31:26

postoperative changes, no additional obvious lytic mass

31:30

lesion, and a larger right-sided pleural effusion with

31:34

decreased left-sided pleural effusion.

31:37

And as you can see, the AI-generated impression correctly

31:41

described the prior fusion and corpectomy with stable

31:45

hardware alignment. However, it also included the marrow

31:49

replacement process involving C11 and

31:52

generated the recommendation as recommended

31:56

oncology follow-up. This recommendation was not included

32:00

in the final radiologist impression.

32:03

This example demonstrates an important safety issue.

32:06

AI systems may generate statements that appear

32:10

clinically plausible but are not part of the

32:13

radiologist's intended conclusion.

32:16

Therefore, even when AI performance is strong

32:19

overall, individual outputs must be reviewed carefully.

32:23

AI-generated impression should be considered as assistive tool,

32:27

not an autonomous supporting system.

32:33

And in

32:37

conclusion, our study demonstrated that

32:39

AI-generated auto impressions can produce

32:43

highly accurate impressions from radiology findings

32:48

across reporting sites and imaging examinations,

32:51

thoracic, and abdominal radiology reports.

32:55

The AI-generated impressions were similar in word count to

32:59

radiologist-dictated impressions, showed high consistency

33:03

with the original findings, and demonstrated strong

33:06

correlation with the radiologist impressions, particularly for clinically

33:10

significant findings. Most AI-generated impressions were

33:14

classified as either perfect or good.

33:17

These findings support the potential role of AI-generated

33:21

impression as an assistive tool for

33:25

improving reporting efficiency.

33:27

However, the examples also demonstrate that clinically meaningful

33:31

discrepancy can occur. Therefore, radiologist

33:34

review remains essential before final report

33:38

approval. Overall, AI-generated auto

33:41

impression may help reduce reporting burden, improve

33:45

consistency, and support workflow efficiency

33:49

while maintaining the radiologist's central role

33:53

in clinical interpretation and final decision-making.

33:57

So thank you everyone for attending this session.

34:00

If there is any question, feel free to ask.

34:12

I can see a few question over here.

34:28

You have focused on impressions. Have you developed software to

34:32

auto-populate the indication section with patient age, sex, and

34:36

clinical indication from referral form and EMR?

34:40

So actually, really good question.

34:43

In this specific AI model, which was developed

34:47

by Nuance Communications, they did not focus on

34:51

this part, and we haven't worked on this part, but this is actually a really nice

34:54

question. And actually, it has

34:58

potential to be worked on. But it was not our focus to work

35:01

on.

35:10

Another question is how many versions of software tested version?

35:15

What is now available? So the thing is, this

35:19

study actually was performed,

35:22

I think, two years ago. Since then, there were a lot of updates and upgrades in

35:26

the

35:28

AI model, especially for the recommendation section.

35:33

And we have been working on another study, which

35:37

would also include the recommendations, and it actually improved

35:41

much better. But

35:44

about how many, like they may be available, to be honest,

35:50

I'm not sure right now, but I know since we worked on this

35:54

study, at least there were three or four more upgrades, which

35:58

right now it's being used in different

36:03

centers.

36:04

And actually, the results were satisfying, to be honest.

36:09

Let me see.

36:22

Actually, this question is really nice, which is for a large radiology

36:26

department, how feasible is it to deploy a local

36:29

LLM on our own reports for draft

36:33

impressions when commercial tools are limited by cost,

36:36

governance, or institutional approval?

36:39

To be honest, because I am in the-- I don't have that much

36:43

experience with this part, I believe that is a better question to be asked from

36:47

a

36:49

computer scientist. But

36:52

I feel this is really actually good question.

36:54

But to be honest,

36:56

I don't have a proper answer for this one.

37:01

I think we addressed all the question I see.

37:04

So thank you, everyone.

37:10

Excellent.

37:13

Good job answering all those questions, doctor.

37:16

Thank you.

37:19

Dr. Kamiani, thank you for your lecture today,

37:23

and thank you for everyone that joined us

37:26

and asked such great questions.

37:29

You can access a recording of today's conference and all our previous noon

37:32

conferences by creating a free account.

37:35

We'll also email out a link to the replay later today.

37:39

Be sure to join us next week on Thursday, August 20th at 12:00 PM

37:43

Eastern, where Dr. Donald Resnick will deliver a lecture

37:47

entitled "Injuries of the Knee: From Conventional Radiography to

37:50

MR Imaging." You can register for that at medallia.com and follow

37:54

us on social media for updates on future noon conferences.

37:58

Thanks again and have a great day.

Report

Tags

Non-Clinical